The ECHO Arrow Hunter PLUS
range of non-invasive flowmeters utilize Transit-time ultrasonic
technology for the accurate flow measurement of clean or dirty liquids in full pipes.
The AH+HH is designed for portable applications where quick setup and flow testing is the primary requirement. The unit is simple, light-weight and cost-effective. It meets and exceeds the measurement performance of any high-priced competitors flowmeter on the market today.
The measurement of flow is based on the principle that sound waves are influenced by a flowing medium. Measurements are made by penetrating the pipe with ultrasound and measuring the frequency variations and phase shifts of the signals received. This measuring technique has no effect on the flowing medium. There is no pressure loss in the pipe and no wear on components of the measuring device.
The ultrasonic sensors are clamped onto the outside of the pipe, thus eliminating the need to dismantle the pipe work and interrupt the process. The AH+HH can be applied to any type of metal or plastic pipe with or without a liner carrying clean or dirty liquids. We have several transducers to chose from depending on pipe size, process temperature and required hazardous approvals.
ECHO Process Instrumentation offers a 60 day Performance Guarantee!
Technical Specs:
Arrow Hunter PLUS – HandHeld
General
Measuring
principle
:
Ultrasonic
Transit-time
Flow
velocity
range
:
0.03 … 82 ft/s (0.01
... 25 m/s)
Resolution
:
0.00082 ft/s (0.25
mm/s)
Repeatability :
0.15
% of measured value ±0.015
m/s
Accuracy
:
Volume
flow :
±
0.5%
factory calibrated (process conditions can reduce accuracy),
±
0.5%
of measured value with process calibration
Flow
velocity :
±
0.5
% of measured value
Turn
down
ratio :
1/100
Max
particulates :
<
10 % of volume
Flow
transmitter
Enclosure : Handheld
Protection
rating :
NEMA 12 (IP
65 according EN60529)
Operating temp. :
14 …140
°F
(-10
... 60 °C)
Housing material : ABS (UL 94 HB)
Flow channels :
1
Power
supply :
Internal rechargeable batteries, 4 x NiMH AA 2850 mAh or 9 VDC external power supply
Display :
LCD
graphic display, 128 x 64, backlight
Dimensions : 8.9
H x 2.8/4.6 W x 1.8 D inch (228 H x 72/117 W x 47 D mm)
Weight :
Approx. 1.5 lbs (0.65 kg)
Power consumption:
< 1 W in measurement mode
Signal damping :
0
... 99 s
Measurement rate
:
10
... 1000 s-1
Operating
languages:
English,
German, French, Spanish
Response
time :
1
s, faster rates upon request
Quantity and units of measurement
Volumetric
flow
rate
:
m3/h,
m3/min, m3/s, l/h, l/min, l/s, USgal/h, USgal/min, USgal/s, USMGD,
bbl/d, bbl/h, bbl/min, bbl/s
Flow
velocity :
m/s,
ft/s, inch/s
Mass
flow
rate :
g/s,
t/h, kg/h, kg/min
Volume/
Mass :
m³,
l,
US gal, bbl /
g,
kg, t
Internal data logger
Storage
capacity :
approx.
30,000 samples (128 kByte), optional > 100,000 samples (512
kByte)
Logging
data :
All
measured and totalized values
Communication
Serial
interface :
RS
232, (optional RS 485)
Data :
Instantaneous
measured value, parameter set and configuration, logged data
Software AH+ PC Software
Functionality :
Downloading
of measured values/parameter sets, graphical presentation, list
format, export to third party software, on-line transfer of measured
data
Operating
systems
:
Windows
2000, NT, XP, Vista, 07
Process
outputs
Serial : RS232 only
Clamp-on Sensors
Type XTT+SM-HH
Pipe Diameter
range:
0.39 … 9.8 inch (10
... 250 mm)
Dimensions
:
1.7 x 0.7 x 0.8 inch (43x18x22mm)
Material
:
Stainless Steel
Temperature
range
:
Type
XTT+SM-HH-ARMOR:
-22 ... 266 °F (-30
...
130 °C)
Protection rating : NEMA 4X (IP 66 acc. EN 60529), Optional NEMA 6P (IP 68) submersible
Hazardous
rating : General Purpose
Type XTT+LG-HH
Pipe Diameter
range:
1.96 … 118 inch (50
... 3000 mm)
Dimensions
:
2.3 x 1.2 x 1.3inch (60x30x34
mm)
Material
:
Stainless Steel
Temperature range : Type XTT+LG-HH-ARMOR: -22 ... 266 °F (-30 ... 130 °C)
Protection rating : NEMA 4X (IP 66 acc. EN 60529), Optional NEMA 6P (IP 68)
Hazardous rating : General Purpose