Level Hunter II and XDS Transducer - Ultrasonic Level Measurement
You're at: Products > Level > Level Hunter II and XDS Transducer - Ultrasonic Level Measurement

Level Hunter II and XDS Transducer - Ultrasonic Level Measurement

Price: $0.00

Part Number Configurator:   (please choose one option per box)


Electronics  (Required) :


Part Number:

LHII

The ECHO LEVEL HUNTER II is an advanced, low cost, ultrasonic level measurement system that utilizes the latest state-of-the-art technology to provide reliable measurement and control. It can accurately measure level and volume (pre-configured tank shapes) and perform alarm and fixed pump control for up to 4 pumps. Standard features include: 1 4-20mA output, 4 SPDT Relays, LED's for alarm/pump status and Quick Setup menu-driven programming. It also comes standard with a RS-232 serial communication port and optional RS-485.

The six buttons allow for easy programming using a quick set up method. No manual needed. Echo Process Instrumentation has eliminated the need for complex parameter programming. It uses a simple question and answer sequence which allows the Level Hunter II to be programmed in minutes. Housed in a rugged NEMA 4X enclosure with easy access to the wiring terminals, the Level Hunter II is the ideal instrument for non-contact ultrasonic level measurement and alarm/pump control.

Big in functionality and small on price, the Level Hunter II is perfect for the toughest applications. We offer a standard 60 day Performance Guarantee and 1 year warranty. We will prove our technology and high quality product is the best in the market and completely risk free to the customer. A totally flexible solution!

-Level Measurement up to 50 ft (15 m)

-Alarm/Pump Control

-Tank farm monitoring

-Overflow and pump dry protection

-Sluce gate control

-Proximity detection


A complete system comprises of 1 Level Hunter II and 1 XDS Transducer to measure and control your level or pumps.

 






Click for more

ECHO Surge Suppression

Price: $425.00

Click for more

Heated Enclosure

Price: $395.00

Click for more

Transducer Sunshield

Price: $180.00

Technical Specifications:  Level Hunter II  

TECHNOLOGY/ OPERATION 
 Measuring Principle                                       Ultrasonic Level Measurement

PERFORMANCE 
Measuring Range                                             Transducer Dependent, 0 - 50 ft  (0 - 15 m)
XDS Transducer Models:                               XDS 08 = 0 - 8m (26ft) range, 0.35m (1.1ft blanking distance)
                                                           
XDS 12 = 0 - 12m (40ft) range, 0.5m (1.6ft blanking distance)
                                                                                XDS 15 = 0 - 15m (50ft) range, 0.5m (1.6ft blanking distance)
Transducer Cable Extensions                     Use 2-conductor/ shielded 16/18 AWG

Accuracy                                                              +/- 0.25% of measured range or 6mm  (whichever is greater)
Response Rate                                                  Fully adjustable (0.1m/min to 100m/min)
Echo Processing                                                ECHO LOGIC Sophisticated algorithms using  Advanced DSP Processing
Power Supply                                                    100 ... 240VAC  50/60 Hz, Optional 24 VDC
Power Consumption                                      Typically <5W, 11W maximum if relays energized

Channels                                                             1

OUTPUTS 
Analog                                                                  1   4-20mA output, 600 ohm
max.
Relay                                                                     4 Form "C" SPDT Relays, 5A @ 250 VAC
Relay Function                                                  High, HiHi, Low, LoLo Alarms
                                                                                Fixed Pump Control
                                                                                Volume High or Low Alarm

Communication                                                Standard RS 232, Optional:  RS 485


PROGRAMMING 
User-interface                                                  6 button integral keypad with menu-driven programming
Display                                                                 2 lines, 40 characters LCD
Relay Indication                                               LED Indication for Relay Status
Programming Security                                   Password protected
Data Integrity                                                    Non-volatile RAM

ENVIRONMENT  
Temperature Range (Electronics)             -4°F to +140°F (-20°C to +60°C)
Temperature Range (Transducer)            -40°F to +158°F  (-40°C to +70°C)
Temperature Compensation                      Integral Temperature Sensor with Automatic Compensation
Outdoor Rating (Electronics)                      NEMA 4X  (IP 65), UV Protected Clear Lid

DESIGN  
Dimensions                                                        7.3H x 9.4W x 4.2W inch (185 x 240 x 107 mm)
Cable Entry                                                         11 available for Wall Mount Enclosure
Mounting                                                            2 fixed holes & 1 hanging hole
Enclosure Material                                          Plastic, ABS, Polycarbonate (transparent front lid)
Weight                                                                 Approximate 3 lbs (1.4 kg)

WARRANTY 
Product Warranty                                            1 year

 TRANSDUCER 
 XDS 08 Dimensions                                       2.6" dia x 5.1" ht  (67mm x 131mm)
 Explosion Proof                                              EEX d II T6               

 XDS 12 Dimensions                                       3.3" dia x 6.0" ht  (84mm x 152mm)
 Explosion Proof                                              EEX d II T6   

 XDS 15 Dimensions                                       4.5" dia x 6.8" ht  (115mm x 173mm)
 Explosion Proof                                              EEX d II T6   

The Level Hunter II and XDS transducer is a complete ultrasonic level measurement system for use in liquid, slurry or solids applications up to 50 ft depending on the sensor chosen.  It is used frequently for pump stations, storage tanks, pond or river level and more.  It is a reliable solution for your level needs.

Please call ECHO to discuss your level application 850-609-1300.
  • Transducer Mounting:  Confirm the XDS transducer is mounted above the highest water level possible to compensate for the Near Blanking Distance .  This is required because any liquid that comes inside this blanking distance will be ignored and cause a loss of echo or wrong level to be displayed.

  • Transducer Shade:  Mount a plate or 1' x 1' plywood over the transducer to shield it from the thermal effects of the sun.  During the hot summer days, the transducer will heat up more than the ambient temperature if not shielded properly.  This will cause slight errors in the flow measurement because the Speed of Sound changes with temperature.  The XDS transducer is temperature compensated automatically.

  • Transducer Location:  Confirm the transducer has a clear shot to the Empty Distance or no flow condition and is mounted perpendicular to the water.